Dentreal V Sensor Intraoral X-Ray Sensor RVG - Sensor Size 1

In stock - 100 items available
SKU: DRM.7676
Regular price $1,000.00
You can contact us for your orders and questions. +90543 456 2614
All your orders are sent by fast air cargo with UPS or DHL Shipping
Your orders will be prepared and shipped within 3 business days.
Customs clearance in your country is not the seller's responsibility.

V-Sensor Intraoral X-Ray Sensor RVG — Size 1

Basket gift campaigns do not apply to this product.

Features

  • Most economical X-ray sensor to date
  • Thinnest X-ray sensor to date — 4.4 mm
  • Bringing pioneering technologies to dentistry
  • Cost per patient 1/10 vs. film
  • 3 s to complete image processing
  • 50,000+ exposures without quality loss
  • Passed 70,000+ bend tests
  • Automatic exposure detection
  • APS CMOS technology for high signal-to-noise ratio
  • User-friendly 4-step software
  • Theoretical resolution 25 lp/mm; true resolution 20 lp/mm
  • AD conversion — 16 bit
  • IP68 — highest water and dust protection rating
  • 2-year sensor warranty (excluding physical damage)

What is an RVG sensor?

RVG stands for RadioVisioGraphy. This technology is used as an alternative to X-ray radiography in dentistry. RVG sensors are developed with durability and image quality in mind. A hermetically sealed sensor housing makes the sensor waterproof for versatile applications. A shock-protection layer protects the sensor from bites and drops. The combination of a high-sensitivity scintillator, fiber optics, and a high-resolution durable CMOS detector helps obtain high-quality images.

How the RVG sensor works

The sensor has two sides — reactive and non-reactive. The reactive side must be used to acquire an image. Tissue is exposed to X-ray radiation and the refracted light is captured by the sensor. The image is processed instantly and converted to digital data via analog-to-digital converters, then sent to the computer for immediate viewing. The cable connection is on the inactive side. If the non-reactive side is exposed to X-ray, no image appears on screen. A USB transfers images to the computer and must be connected. The X-ray generator used must operate between 60 kV and 70 kV; generators below 60 kV are not compatible. If images appear too dark, reduce exposure time; if grainy, increase exposure time. Generator type also affects image quality.

Advantages

  • Reduces X-ray exposure time for dental imaging
  • Compared with conventional radiology methods, reduces patient X-ray exposure by about 80%
  • Instant results for the clinician and shorter patient waiting times
  • Flexibility to save images and change size or contrast for better viewing

Size 1 technical data

  • Detector technology: APS CMOS
  • Scintillator: CsI
  • Pixel matrix: 1000×1500
  • Theoretical resolution: 25 lp/mm
  • True resolution: 20 lp/mm
  • Active area: 20×30 mm
  • Mechanical size: 25.4×36.8×4.4 mm
  • AD conversion: 16 bit
  • Data interface: USB 2.0
  • Protection: IP68